← Back to McFlusion

Overview

McFlusion standalone SIP system

The SS Series is McFlusion’s standalone, sterilize-in-place unit for the Life Sciences, biopharma, and vaccine industries. It is a dedicated SIP unit that delivers steam to a connected process item and runs the sterilization cycle on its own, separate from any cleaning equipment. It comes in two configurations: a portable version on McFlusion’s AISI 304 SS wheeled frame that can be moved to the equipment that needs sterilizing, and a compact wall or floor mounted version for a fixed installation where a permanent SIP point is preferred.

Each SS unit runs on McFlusion’s modular hardware and software platform: an Allen-Bradley CompactLogix PLC and a 12 inch PC-based touchscreen HMI, with full TACCT parameter control, a recipe editor, alarm handling, and cycle reporting to PDF. Full instrumentation covers level, pressure, flow, temperature, and conductivity, and the operator can adjust pressure, flow rate, temperature, and chemical concentration directly from the HMI.

As a Life Sciences unit, the SS Series adds Process Builder Design (PBD) for software integration, AutoTune for automatic optimization of flow paths, and a Data Collection System (DCS) in TECH or GMP variants. SIP cycles run against F0 set points with pass/fail criteria, with cold spot monitoring at the lowest and hardest-to-heat points of the load.

AISI 316L stainless steel wetted parts. Supplied with full system design and QA documentation.

SS Portable SIP Unit Specifications

SIP supply pressure<60 PSI
SIP supply temperature<302 °F
SIP return pressure / vacuum-14.5 to 90 PSI
Optional modulating steam valve4-20 mA
Dimensions (L×W×H)60 × 26 × 70″
Weight, dry~750 lbs
FrameAISI 304 SS, wheeled
Wetted partsAISI 316L SS

SS Wall or Floor Mounted SIP Unit Specifications

SIP supply pressure<60 PSI
SIP supply temperature<302 °F
SIP return pressure / vacuum-14.5 to 90 PSI
Dimensions (W×D×H)28 × 10 × 40″
Weight, dry~225 lbs
MountingWall or floor mounted, fixed installation

Sterilization Cycle Parameters

Steam temperature121 to 150 °C (250 to 302 °F)
Steam pressureUp to 60 PSI
F0 valueAccumulated lethality (time at temperature), with pass/fail criteria
Cold spot monitoringTemperature sensors at the lowest and hardest-to-heat points
Control platformAllen-Bradley CompactLogix PLC, 12″ touchscreen HMI

Key Features

Dedicated Standalone SIP

A SIP-only unit that delivers steam and runs the sterilization cycle on its own, separate from cleaning equipment, so a process item can be sterilized without a combined system.

Portable Wheeled Frame

The AISI 304 SS frame is mounted on wheels, so the unit can be brought to the homogenizer, filter station, or vessel that needs sterilizing rather than tied to one location.

F0-Verified Cycles

Sterilization runs against F0 set points with pass/fail criteria, recording accumulated lethality as time at temperature for each cycle.

Cold Spot Monitoring

Temperature sensors placed at the lowest and hardest-to-heat points confirm that the whole load reaches the required sterilization conditions.

Allen-Bradley Control Platform

A CompactLogix PLC and 12 inch PC-based touchscreen HMI provide TACCT parameter control, a recipe editor, alarm handling, and cycle reporting to PDF.

Life Sciences Data Collection

Process Builder Design and AutoTune support integration and flow path optimization, with a Data Collection System available in TECH or GMP variants plus full QA documentation.

Applications

  • Homogenizers
  • Aseptic fill lines with isolator technology
  • Filter stations
  • Formulation and holding vessels
  • Bioreactors
  • Ultrafiltration skids
  • Freeze dryers
  • Glove box isolators

MHS Pharma — Northeast US Representative

MHS Pharma provides direct technical representation for McFlusion across the Northeast United States. Contact us to discuss standalone sterilize-in-place for your process equipment.

Get in Touch
Scroll to Top